40KVA/36KW Long Run On-line Smart UPS 3:3 Phase, RTLong Run On-line Smart UPS, KSTAR YDC3340H
YDC3340 H requires ± 192/204/216/228/240 V DC, which is achieved by connecting 32/34/36/38/40 12V batteries in series.
Description
YDC3340 H requires ± 192/204/216/228/240 V DC, which is achieved by connecting 32/34/36/38/40 12V batteries in series.
The YDC3340 H series UPS devices are high-reliability, three-phase systems designed with input and output voltage isolation. This feature ensures the protection of connected equipment from damage caused by electrical parameter fluctuations in the network. In the event of a power outage, these UPS systems seamlessly switch to backup power without delay. External batteries with capacities of up to 200 AH can be connected, enabling extended autonomous operation of devices. If needed, the UPS units can be connected in parallel, enhancing the system's overall capacity. Used for powering critical three-phase loads, such as industrial automation systems, servers and data centers, financial transaction systems, medical equipment, and more. Functional capabilities Double ConversionPure Sine WaveZero Transfer Time to Backup PowerInterface: REPO, RS232, RS485, USB, SNMP/Dry Contact SlotN+1 Parallel RedundancyGenerator CompatibilityComprehensive Protection Features Conditions for Warranty Coverage The installation of the device must be carried out by a qualified electrical engineer in full compliance with all rules outlined in the official installation manual.
The device must be connected to a grounding system that meets the standards defined by Georgian legislation.
The device must be protected from industrial and natural dust, and the temperature and humidity conditions must comply with the requirements specified in the technical documentation.
Post-installation inspection and activation must be performed by a representative of. Activation of the device without the presence of an representative is strictly prohibited.
If you are using a generator with a distorted output signal, it is important to enable generator mode on the uninterruptible power supply (UPS).
Key specifications: - Autonomy Working Period: Long Run - requires batteries - volt-ampere: 40000 VA - Active power: 36000 W - Number of Phases: 3 - Nominal input voltage range: 208 V - 478 V - Nominal output voltage: 380 V - Frequency range: 45 Hz - 55 Hz - Output frequency: 50 ±0.1% Hz - Parallel Redundancy: Yes - With Transformer: No - Waveform: Pure Sine Wave - Efficiency: 94.5 % - Bypass: Yes - Automatic restart on AC recovery: Yes - Generator compatible: Yes - Cold start function: Yes - Self-Diagnosis: Yes - LCD panel for option: Yes - USB Port for management: Yes - SNMP card slot: Yes - Power terminal: Yes - Operating temperature: 0 °C - 40 °C - Weight: 73 kg
Specifications
Delivery and warranty
Delivery within Tbilisi costs 6 GEL; orders over 150 GEL are delivered free of charge.
Delivery to the regions starts from 11 GEL (for further details, contact us at +995 558 434 888).
Payment: by bank transfer against an invoice, issued as soon as you order. Card payment is coming soon.
Warranty: at least 12 months.